FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource Requirements/FHIR Server from package hl7.ehrs.ehrsfmr21#current (31 ms)

Package hl7.ehrs.ehrsfmr21
Type Requirements
Id Id
FHIR Version R5
Source http://hl7.org/ehrs/https://build.fhir.org/ig/mvdzel/ehrsfm-fhir-r5/Requirements-EHRSFMR2.1-CPS.6.3.html
Url http://hl7.org/ehrs/Requirements/EHRSFMR2.1-CPS.6.3
Version 2.1.0
Status active
Date 2024-11-26T16:30:50+00:00
Name CPS_6_3_Support_for_Safe_Blood_Administration
Title CPS.6.3 Support for Safe Blood Administration (Function)
Experimental False
Realm uv
Authority hl7
Description Facilitate real-time checks for potential blood administration errors.
Purpose To reduce errors at the time of blood product administration, the system assists in positive patient identification, along with checks and alerts regarding the blood product to be administered, including the identification of the blood product, the amount to be delivered, and the route and time of the administration of the blood product.

Resources that use this resource

No resources found


Resources that this resource uses

No resources found



Narrative

Note: links and images are rebased to the (stated) source

Statement N:

Facilitate real-time checks for potential blood administration errors.

Description I:

To reduce errors at the time of blood product administration, the system assists in positive patient identification, along with checks and alerts regarding the blood product to be administered, including the identification of the blood product, the amount to be delivered, and the route and time of the administration of the blood product.

Criteria N:
CPS.6.3#01 SHALL

The system SHALL present, at the time of administration, information necessary to correctly identify the patient and accurately administer blood products including patient name, blood product number, amount, route, product expiration date and time of administration.

CPS.6.3#02 SHALL

The system SHALL provide the ability to capture validation of the correct matching of the patient to the blood product.

CPS.6.3#03 SHALL

The system SHALL provide the ability to capture the blood product number, amount, route and time of administration.

CPS.6.3#04 SHALL

The system SHALL conform to function [[CP.3.2]] (Manage Patient Clinical Measurements) and capture the blood pressure, temperature, pulse and respiration rate of the patient receiving the product.


Source

{
  "resourceType" : "Requirements",
  "id" : "EHRSFMR2.1-CPS.6.3",
  "meta" : {
    "profile" : [
      "http://hl7.org/ehrs/StructureDefinition/FMFunction"
    ]
  },
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <span id=\"description\"><b>Statement <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b> <div><p>Facilitate real-time checks for potential blood administration errors.</p>\n</div></span>\n\n \n <span id=\"purpose\"><b>Description <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Informative Content\" class=\"informative-flag\">I</a>:</b> <div><p>To reduce errors at the time of blood product administration, the system assists in positive patient identification, along with checks and alerts regarding the blood product to be administered, including the identification of the blood product, the amount to be delivered, and the route and time of the administration of the blood product.</p>\n</div></span>\n \n\n \n\n \n <span id=\"requirements\"><b>Criteria <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b></span>\n \n <table id=\"statements\" class=\"grid dict\">\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>CPS.6.3#01</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL present, at the time of administration, information necessary to correctly identify the patient and accurately administer blood products including patient name, blood product number, amount, route, product expiration date and time of administration.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>CPS.6.3#02</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to capture validation of the correct matching of the patient to the blood product.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>CPS.6.3#03</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to capture the blood product number, amount, route and time of administration.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>CPS.6.3#04</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL conform to function [[CP.3.2]] (Manage Patient Clinical Measurements) and capture the blood pressure, temperature, pulse and respiration rate of the patient receiving the product.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n </table>\n</div>"
  },
  "url" : "http://hl7.org/ehrs/Requirements/EHRSFMR2.1-CPS.6.3",
  "version" : "2.1.0",
  "name" : "CPS_6_3_Support_for_Safe_Blood_Administration",
  "title" : "CPS.6.3 Support for Safe Blood Administration (Function)",
  "status" : "active",
  "date" : "2024-11-26T16:30:50+00:00",
  "publisher" : "EHR WG",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/ehr"
        }
      ]
    }
  ],
  "description" : "Facilitate real-time checks for potential blood administration errors.",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001",
          "display" : "World"
        }
      ]
    }
  ],
  "purpose" : "To reduce errors at the time of blood product administration, the system assists in positive patient identification, along with checks and alerts regarding the blood product to be administered, including the identification of the blood product, the amount to be delivered, and the route and time of the administration of the blood product.",
  "statement" : [
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-CPS.6.3-01",
      "label" : "CPS.6.3#01",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL present, at the time of administration, information necessary to correctly identify the patient and accurately administer blood products including patient name, blood product number, amount, route, product expiration date and time of administration.",
      "derivedFrom" : "EHR-S_FM_R1.1 DC.2.4.5.1#1"
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-CPS.6.3-02",
      "label" : "CPS.6.3#02",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL provide the ability to capture validation of the correct matching of the patient to the blood product.",
      "derivedFrom" : "EHR-S_FM_R1.1 DC.2.4.5.1#2"
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-CPS.6.3-03",
      "label" : "CPS.6.3#03",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL provide the ability to capture the blood product number, amount, route and time of administration.",
      "derivedFrom" : "EHR-S_FM_R1.1 DC.2.4.5.1#3"
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-CPS.6.3-04",
      "label" : "CPS.6.3#04",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL conform to function [[CP.3.2]] (Manage Patient Clinical Measurements) and capture the blood pressure, temperature, pulse and respiration rate of the patient receiving the product.",
      "derivedFrom" : "EHR-S_FM_R1.1 DC.2.4.5.1#4"
    }
  ]
}